Assessment Year | 1987 |
---|---|
Principal Product | WOOD DINING TABLES |
NAICS |
n/a
|
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 137,500
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,545 | 1,170,574 |
kWh
|
$0.065 |
Wood | $8,571 | 6,880 |
MMBtu
|
$1.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,892 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,892 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $11,075 | $3,418 |
$4,475
98,769
kWh
|
$6,000
-
MMBtu
|
$600 | |
02 | 2.4133: Use most efficient type of electric motors | $412 | $562 |
$412
6,448
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,924 | $4,140 |
$1,924
29,894
kWh
|
- | - | |
04 | 2.4312: Improve lubrication practices | $1,159 | - |
$1,159
17,878
kWh
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $758 | - |
$758
11,723
kWh
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $564 | $900 |
$564
8,792
kWh
|
- | - | |
TOTAL RECOMMENDED | $15,892 | $9,020 |
$9,292
173,504
kWh
|
$6,000
-
MMBtu
|
$600 | ||
TOTAL IMPLEMENTED | $15,892 | $9,020 |
$9,292
173,504
kWh
|
$6,000
-
MMBtu
|
$600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Wood Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs