Assessment Year | 1987 |
---|---|
Principal Product | COTTON FABRIC |
NAICS |
n/a
|
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | $10 M to 50M |
# of Employees | 245 |
Plant Area |
n/a
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $352,164 | 7,628,077 |
kWh
|
$0.046 |
Natural Gas | $555,723 | 205,295 |
MMBtu
|
$2.71 |
Fuel Oil #2 | $32,171 | 7,798 |
MMBtu
|
$4.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $101,098 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,641 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $31,324 | $10,000 | - |
$31,324
-
MMBtu
|
|
02 | 2.2414: Use waste heat from hot flue gases to preheat | $10,654 | $12,000 | - |
$10,654
-
MMBtu
|
|
03 | 2.2531: Re-size charging openings or add movable cover or door | $22,702 | $5,000 | - |
$22,702
-
MMBtu
|
|
04 | 2.2121: Increase amount of condensate returned | $9,822 | $1,000 | - |
$9,822
-
MMBtu
|
|
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $6,988 | $6,000 | - |
$6,988
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,220 | $865 |
$5,220
112,837
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,813 | $22,500 |
$5,813
126,026
kWh
|
- | |
08 | 2.4133: Use most efficient type of electric motors | $2,139 | $1,152 |
$2,139
46,307
kWh
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $697 | $800 |
$697
15,240
kWh
|
- | |
10 | 2.2437: Recover waste heat from equipment | $1,297 | $3,000 |
$1,297
145,662
kWh
|
- | |
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,708 | - |
$2,708
58,617
kWh
|
- | |
12 | 2.7226: Use computer programs to optimize hvac performance | $1,734 | $1,500 |
$1,734
37,515
kWh
|
- | |
TOTAL RECOMMENDED | $101,098 | $63,817 |
$19,608
542,204
kWh
|
$81,490
-
MMBtu
|
||
TOTAL IMPLEMENTED | $44,641 | $46,517 |
$17,177
489,449
kWh
|
$27,464
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs