Assessment Year | 1987 |
---|---|
Principal Product | DENIM YARN |
NAICS |
n/a
|
SIC | 2211: Broadwoven Fabric Mills, Cotton |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
n/a
|
Annual Production | 32,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,309,960 | 29,318,875 |
kWh
|
$0.045 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,610 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,502 | $100 |
$22,502
506,448
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,610 | - |
$6,610
148,886
kWh
|
- | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $982 | $2,500 |
$1,888
42,497
kWh
|
$(-906.0)
-
MMBtu
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $99 | $150 |
$99
2,345
kWh
|
- | |
TOTAL RECOMMENDED | $30,193 | $2,750 |
$31,099
700,176
kWh
|
$(-906.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,610 | - |
$6,610
148,886
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs