ITAC Assessment: AT0065
ITAC logo
ITAC Assessment: AT0065
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product MOLDED PLASTIC PRODUCTS
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 170
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 6,600
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $535,957 9,163,247
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $60,507 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,754

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.2614: Use cooling tower or economizer to replace chiller cooling $10,589 $3,000 $10,589
181,125
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $12,448 $10,000 $12,448
212,778
kWh
-
03 2.5194: Redesign process $2,779 $6,000 $2,779
47,479
kWh
-
04 2.7226: Use computer programs to optimize hvac performance $26,038 $4,000 $26,038
445,193
kWh
-
05 2.4312: Improve lubrication practices $4,191 - $11,811
201,934
kWh
$(-7,620.0)
06 2.4133: Use most efficient type of electric motors $2,960 $1,685 $2,960
50,703
kWh
-
07 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $1,196 $1,800 $1,196
20,516
kWh
-
08 2.4221: Install compressor air intakes in coolest locations $306 $500 $306
5,275
kWh
-
TOTAL RECOMMENDED $60,507 $26,985 $68,127
1,165,003
kWh
$(-7,620.0)
TOTAL IMPLEMENTED $12,754 $10,500 $12,754
218,053
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings