ITAC Assessment: AT0049
ITAC logo
ITAC Assessment: AT0049
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1986
Principal Product FABRICATED BOARDS
NAICS
n/a
SIC 2499: Wood Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area
n/a
Annual Production 5,500
thousand feet
Production Hrs. Annual 4,080
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $227,311 4,378,077
kWh
Wood $43,000 43,000
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $31,784 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,325

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.4133: Use most efficient type of electric motors $3,135 $1,957 $3,135
60,375
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $3,090 $3,879 $3,090
59,496
kWh
-
03 2.4312: Improve lubrication practices $23,459 - $26,361
507,620
kWh
$(-2,902.0)
04 2.4221: Install compressor air intakes in coolest locations $2,100 $500 $2,100
40,445
kWh
-
TOTAL RECOMMENDED $31,784 $6,336 $34,686
667,936
kWh
$(-2,902.0)
TOTAL IMPLEMENTED $8,325 $6,336 $8,325
160,316
kWh
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs