Assessment Year | 1986 |
---|---|
Principal Product | FIBER (NYLON) |
NAICS |
n/a
|
SIC | 2281: Yarn Spinning Mills |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,521 | 1,004,982 |
kWh
|
$0.065 |
Natural Gas | $45,819 | 5,849 |
MMBtu
|
$7.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,089 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,705 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $593 | $159 |
$593
9,965
kWh
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,844 | $1,000 | - |
$1,844
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,530 | $3,300 |
$1,530
25,498
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,268 | $250 |
$1,268
21,102
kWh
|
- | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,854 | $2,500 |
$1,854
(-16,706)
kWh
|
- | |
TOTAL RECOMMENDED | $7,089 | $7,209 |
$5,245
39,859
kWh
|
$1,844
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,705 | $1,409 |
$1,861
31,067
kWh
|
$1,844
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs