| Assessment Year | 1986 |
|---|---|
| Principal Product | AIRPLANE SEATS(COMMERCIAL) |
| NAICS |
n/a
|
| SIC | 2531: Public Building and Related Furniture |
| Sales Range | $10 M to 50M |
| # of Employees | 450 |
| Plant Area |
n/a
|
| Annual Production | 28,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $277,467 | 5,533,118 |
kWh
|
$0.050 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $2,442 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $897 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $587 | $332 |
$587
11,723
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $245 | $360 |
$245
4,982
kWh
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $652 | $250 |
$652
12,896
kWh
|
|
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $958 | - |
$958
19,050
kWh
|
|
| TOTAL RECOMMENDED | $2,442 | $942 |
$2,442
48,651
kWh
|
||
| TOTAL IMPLEMENTED | $897 | $610 |
$897
17,878
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs