Assessment Year | 1985 |
---|---|
Principal Product | CORRUCATED SHEETS |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
n/a
|
Annual Production | 684
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,897 | 1,441,970 |
kWh
|
$0.046 |
Natural Gas | $174,920 | 35,567 |
MMBtu
|
$4.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,475 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,475 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $449 | $422 |
$449
9,672
kWh
|
- | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $17,673 | $300 | - |
$17,673
-
MMBtu
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $394 | - |
$394
8,499
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $272 | $250 |
$272
5,862
kWh
|
- | |
05 | 2.7226: Use computer programs to optimize hvac performance | $830 | $450 |
$830
17,878
kWh
|
- | |
06 | 2.2122: Install / repair insulation on condensate lines | $2,293 | $1,920 | - |
$2,293
-
MMBtu
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,564 | $205 |
$1,564
33,705
kWh
|
- | |
TOTAL RECOMMENDED | $23,475 | $3,547 |
$3,509
75,616
kWh
|
$19,966
-
MMBtu
|
||
TOTAL IMPLEMENTED | $23,475 | $3,547 |
$3,509
75,616
kWh
|
$19,966
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs