Assessment Year | 1985 |
---|---|
Principal Product | OFFICE FURNITURE |
NAICS |
n/a
|
SIC | 2521: Wood Office Furniture |
Sales Range | $10 M to 50M |
# of Employees | 285 |
Plant Area |
n/a
|
Annual Production | 150,000
pieces
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,500 | 891,852 |
kWh
|
$0.062 |
Natural Gas | $18,419 | 2,946 |
MMBtu
|
$6.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,981 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,902 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $191 | $324 |
$191
2,931
kWh
|
|
02 | 2.7226: Use computer programs to optimize hvac performance | $888 | $1,050 |
$888
14,361
kWh
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $421 | - |
$421
6,741
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $274 | $500 |
$274
4,396
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $227 | $270 |
$227
3,810
kWh
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $277 | $150 |
$277
4,396
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,703 | $658 |
$2,703
43,669
kWh
|
|
TOTAL RECOMMENDED | $4,981 | $2,952 |
$4,981
80,304
kWh
|
||
TOTAL IMPLEMENTED | $3,902 | $1,578 |
$3,902
63,012
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs