Assessment Year | 1985 |
---|---|
Principal Product | ALUMINUM DIE CASTINGS |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
n/a
|
Annual Production | 8,000,000
ton
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $169,889 | 3,681,125 |
kWh
|
$0.046 |
Natural Gas | $390,188 | 72,080 |
MMBtu
|
$5.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,210 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,145 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $4,589 | $3,535 |
$4,589
99,648
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $243 | $36 |
$243
5,275
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,082 | $933 |
$1,082
23,447
kWh
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,476 | - |
$1,476
32,239
kWh
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $820 | $500 |
$820
17,878
kWh
|
|
TOTAL RECOMMENDED | $8,210 | $5,004 |
$8,210
178,487
kWh
|
||
TOTAL IMPLEMENTED | $2,145 | $1,469 |
$2,145
46,600
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs