| Assessment Year | 2026 |
|---|---|
| Principal Product | security and defense |
| NAICS | 334511: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufactur |
| SIC | 3812: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical Systems and Instruments |
| Sales Range | less than $500 k |
| # of Employees | 280 |
| Plant Area |
262,783
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,608,487 | 42,253,396 |
kWh
|
$0.062 | |
| Electricity Demand | $1,501,040 | 91,362 |
kW-mo/yr
|
$16.43 | |
| Electricity Fees | $450,142 | - |
|
- | |
| Natural Gas | $182,313 | 39,620 |
MMBtu
|
$4.60 | |
| Waste Disposal Costs | |||||
| Water Usage | $120,115 | 76,554 |
Tgal
|
$1.57 | |
| Other Liquid (non-haz) | $19,906 | 1 |
gal
|
$19,906.00 | |
| TOTAL YEARLY COSTS | $4,882,003 | ||||
| RECOMMENDED SAVINGS* | $73,608 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2622: Replace existing chiller with high efficiency model | $49,530 | $1,368,217 |
$4,249
68,860
kWh
|
$4,781
-
kW-mo/yr
|
- | $40,500 | |
| 02 | 2.2628: Utilize a less expensive cooling method | $15,368 | $53,246 |
$2,878
46,644
kWh
|
$3,490
-
kW-mo/yr
|
- | $9,000 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,721 | $9,419 |
$2,691
43,701
kWh
|
$2,423
-
kW-mo/yr
|
$1,607 | - | |
| 04 | 2.7272: Install heat pipes / raise cooling setpoint | $1,361 | $79 |
$658
10,661
kWh
|
$703
-
kW-mo/yr
|
- | - | |
| 05 | 2.2511: Insulate bare equipment | $236 | $4,880 |
$115
1,855
kWh
|
$121
-
kW-mo/yr
|
- | - | |
| 06 | 2.6232: Install set-back timers | $178 | $636 |
$178
2,878
kWh
|
- | - | - | |
| 07 | 2.7144: Install spectral reflectors / delamp | $118 | $72 |
$60
968
kWh
|
$49
-
kW-mo/yr
|
- | $9 | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $96 | $866 |
$32
526
kWh
|
$64
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $73,608 | $1,437,415 |
$10,861
176,093
kWh
|
$11,631
-
kW-mo/yr
|
$1,607 | $49,509 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs