ITAC Assessment: AS0596
ITAC logo
ITAC Assessment: AS0596
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product theatrical producers and services
NAICS 711310: Promoters of Performing Arts, Sports, and Similar Events with Facilities
SIC 7922: Theatrical Producers (Except Motion Picture) and Miscellaneous Theatrical Services
Sales Range less than $500
k
# of Employees 100
Plant Area 96,237
ft2
Annual Production 1
units
Production Hrs. Annual 8,760
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $185,177 2,144,199
kWh
Electricity Demand $16,224 7,768
kW-mo/yr
Natural Gas $286,767 22,133
MMBtu
Other Energy $85,061 1
MMBtu
Waste Disposal Costs
Water Usage $322 148
Tgal
Water Disposal $366 148
Tgal
TOTAL YEARLY COSTS $573,917
RECOMMENDED SAVINGS* $48,041 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 4.611: Begin a practice of predictive / preventative maintenance $33,561 $47,970 - - $33,561
-
MMBtu
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,811 $13,729 $8,797
96,844
kWh
$498
-
kW-mo/yr
- $1,516
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,510 $2,834 $1,462
16,920
kWh
$48
-
kW-mo/yr
- -
04 2.6211: Conserve energy by efficient use of vending machines $1,357 $716 $1,289
14,915
kWh
$68
-
kW-mo/yr
- -
05 2.7261: Install timers and/or thermostats $755 $1,959 $755
8,728
kWh
- - -
06 2.1232: Keep boiler tubes clean $47 $83 - - $47
-
MMBtu
-
TOTAL RECOMMENDED $48,041 $67,291 $12,303
137,407
kWh
$614
-
kW-mo/yr
$33,608
-
MMBtu
$1,516
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs