Assessment Year | 2024 |
---|---|
Principal Product | plastic car parts |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 68 |
Plant Area |
67,000
ft2
|
Annual Production | 350,000,000
units
|
Production Hrs. Annual | 5,760
hrs
|
Location (State) | New Mexico |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $75,817 | 2,173,631 |
kWh
|
$0.035 | |
Electricity Demand | $85,788 | 5,345 |
kW-mo/yr
|
$16.05 | |
Electricity Fees | $21,665 | - |
|
- | |
Natural Gas | $11,648 | 2,016 |
MMBtu
|
$5.78 | |
Other Energy | $1,763 | 1 |
MMBtu
|
$1,763.00 | |
Waste Disposal Costs | |||||
Water Usage | $17,000 | 3,213 |
Tgal
|
$5.29 | |
Water Disposal | $2,328 | 3,213 |
Tgal
|
$0.72 | |
TOTAL YEARLY COSTS | $216,009 | ||||
RECOMMENDED SAVINGS* | $1,774,258 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.114: Add/modify equipment to improve drying process | $932,699 | $336,920 |
$(-4,396.0)
(-125,950)
kWh
|
- | $(-25,000.0) | - | $962,095 | |
02 | 3.2176: Increase use of automation | $795,203 | $2,763,501 | - | - | - | - | $795,203 | |
03 | 2.9114: Use solar heat to make electricty | $40,380 | $545,958 |
$26,906
770,940
kWh
|
$13,474
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,359 | $7,359 |
$1,207
34,570
kWh
|
$1,158
-
kW-mo/yr
|
- | $(-6.0) | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,272 | $5,188 |
$650
18,620
kWh
|
$622
-
kW-mo/yr
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $643 | $1,397 |
$397
11,362
kWh
|
$246
-
kW-mo/yr
|
- | - | - | |
07 | 2.7226: Use computer programs to optimize hvac performance | $530 | $1,940 |
$174
4,992
kWh
|
$356
-
kW-mo/yr
|
- | - | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $487 | $1,215 |
$278
7,971
kWh
|
$209
-
kW-mo/yr
|
- | - | - | |
09 | 2.7144: Install spectral reflectors / delamp | $407 | $324 |
$34
983
kWh
|
$33
-
kW-mo/yr
|
- | $340 | - | |
10 | 2.7272: Install heat pipes / raise cooling setpoint | $278 | $454 |
$142
4,085
kWh
|
$136
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $1,774,258 | $3,664,256 |
$25,392
727,573
kWh
|
$16,234
-
kW-mo/yr
|
$(-25,000.0) | $334 | $1,757,298 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs