Assessment Year | 2024 |
---|---|
Principal Product | Load Cells |
NAICS | 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3829: Measuring and Controlling Devices, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 260 |
Plant Area |
50,000
ft2
|
Annual Production | 35,000
units
|
Production Hrs. Annual | 5,188
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $199,045 | 1,968,276 |
kWh
|
$0.10 |
Electricity Demand | $53,150 | 4,972 |
kW-mo/yr
|
$10.69 |
Electricity Fees | $26,871 | - |
|
- |
TOTAL YEARLY COSTS | $279,066 | |||
RECOMMENDED SAVINGS* | $118,359 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $83,415 | $500 | - | - | $16,683 | - | $66,732 | |
02 | 2.8112: Combine utility meters | $17,621 | $303 |
$12,797
-
kWh
|
$3,200
-
kW-mo/yr
|
$1,624 | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,624 | $11,409 |
$4,136
40,879
kWh
|
$1,905
-
kW-mo/yr
|
- | $3,583 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,247 | $140 |
$1,975
19,535
kWh
|
$272
-
kW-mo/yr
|
- | - | - | |
05 | 4.611: Begin a practice of predictive / preventative maintenance | $1,811 | $4,800 |
$1,811
17,913
kWh
|
- | - | - | - | |
06 | 2.7226: Use computer programs to optimize hvac performance | $1,799 | $1,992 |
$1,317
13,031
kWh
|
$482
-
kW-mo/yr
|
- | - | - | |
07 | 2.7144: Install spectral reflectors / delamp | $958 | $84 |
$587
5,811
kWh
|
$143
-
kW-mo/yr
|
- | $228 | - | |
08 | 2.7135: Install occupancy sensors | $701 | $1,212 |
$468
4,614
kWh
|
$233
-
kW-mo/yr
|
- | - | - | |
09 | 2.7132: Install timers on light switches in little used areas | $111 | $290 |
$111
1,100
kWh
|
- | - | - | - | |
10 | 2.7444: Close holes and openings in building such as broken windows | $72 | $125 |
$55
541
kWh
|
$17
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $118,359 | $20,855 |
$23,257
103,424
kWh
|
$6,252
-
kW-mo/yr
|
$18,307 | $3,811 | $66,732 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs