ITAC Assessment: AS0502
ITAC logo
ITAC Assessment: AS0502
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product Crushing and conveying equipment
NAICS 333922: Conveyor and Conveying Equipment Manufacturing
SIC 3535: Conveyors and Conveying Equipment
Sales Range $10
M
to 50
M
# of Employees 90
Plant Area 75,000
ft2
Annual Production 17,720
units
Production Hrs. Annual 5,559
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $66,010 1,520,960
kWh
Electricity Demand $115,296 6,022
kW-mo/yr
Electricity Fees $6,921 -
Natural Gas $47,272 7,556
MMBtu
Waste Disposal Costs
Water Usage $6,917 774
Tgal
TOTAL YEARLY COSTS $242,416
RECOMMENDED SAVINGS* $34,977 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,623

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.8114: Change rate schedules or other changes in utility service $12,647 $200 $(-7,365.0)
-
kWh
$20,012
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $11,703 $13,532 $6,141
142,802
kWh
$5,646
-
kW-mo/yr
$(-84.0)
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,685 $2,400 $5,410
125,807
kWh
$3,275
-
kW-mo/yr
-
04 2.6211: Conserve energy by efficient use of vending machines $672 $284 $415
9,647
kWh
$257
-
kW-mo/yr
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $393 $1,127 $211
4,898
kWh
$182
-
kW-mo/yr
-
06 2.4221: Install compressor air intakes in coolest locations $359 $793 $143
3,322
kWh
$216
-
kW-mo/yr
-
07 2.7135: Install occupancy sensors $350 $1,131 $350
8,134
kWh
- -
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $168 $375 $105
2,430
kWh
$63
-
kW-mo/yr
-
TOTAL RECOMMENDED $34,977 $19,842 $5,410
297,040
kWh
$29,651
-
kW-mo/yr
$(-84.0)
TOTAL IMPLEMENTED $12,623 $15,827 $6,600
153,452
kWh
$6,107
-
kW-mo/yr
$(-84.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings