| Assessment Year | 2020 |
|---|---|
| Principal Product | Cement/Ready Mix Concrete |
| NAICS | 327320: Ready-Mix Concrete Manufacturing |
| SIC | 3273: Ready-Mixed Concrete |
| Sales Range | less than $500 k |
| # of Employees | 30 |
| Plant Area |
2,000
ft2
|
| Annual Production | 60,500
units
|
| Production Hrs. Annual | 3,484
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $40,914 | 617,692 |
kWh
|
$0.066 | |
| Electricity Demand | $27,132 | 3,166 |
kW-mo/yr
|
$8.57 | |
| Electricity Fees | $3,464 | - |
|
- | |
| Other Energy | $455,131 | 23,153 |
MMBtu
|
$19.66 | |
| Waste Disposal Costs | |||||
| Water Usage | $60,164 | 11,287 |
Tgal
|
$5.33 | |
| TOTAL YEARLY COSTS | $586,805 | ||||
| RECOMMENDED SAVINGS* | $22,225 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $16,831 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $11,090 | $200 | - | - | $11,090 | |
| 02 | 2.8112: Combine utility meters | $5,394 | $416 | - | - | $5,394 | |
| 03 | 2.6231: Utilize controls to operate equipment only when needed | $4,701 | $160 |
$4,418
66,744
kWh
|
$283
-
kW-mo/yr
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,040 | $1,459 |
$731
10,452
kWh
|
$309
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $22,225 | $2,235 |
$5,149
77,196
kWh
|
$592
-
kW-mo/yr
|
$16,484 | ||
| TOTAL IMPLEMENTED | $16,831 | $1,819 |
$5,149
77,196
kWh
|
$592
-
kW-mo/yr
|
$11,090 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs