Assessment Year | 2020 |
---|---|
Principal Product | Coated Paper Bags |
NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | less than $500 k |
# of Employees | 60 |
Plant Area |
100,000
ft2
|
Annual Production | 2,130,000,000
pieces
|
Production Hrs. Annual | 8,520
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $270,802 | 4,745,859 |
kWh
|
$0.057 |
Electricity Demand | $59,151 | 7,609 |
kW-mo/yr
|
$7.77 |
Electricity Fees | $9,036 | - |
|
- |
TOTAL YEARLY COSTS | $338,989 | |||
RECOMMENDED SAVINGS* | $38,359 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,036 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4226: Use / purchase optimum sized compressor | $17,992 | $66,000 |
$15,210
266,842
kWh
|
$2,782
-
kW-mo/yr
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,276 | $9,045 |
$8,691
152,481
kWh
|
$1,585
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,044 | $9,363 |
$6,747
118,368
kWh
|
$1,297
-
kW-mo/yr
|
|
04 | 2.7232: Replace existing hvac unit with high efficiency model | $1,442 | $5,500 |
$968
16,994
kWh
|
$474
-
kW-mo/yr
|
|
05 | 2.7135: Install occupancy sensors | $605 | $2,300 |
$605
10,612
kWh
|
- | |
TOTAL RECOMMENDED | $38,359 | $92,208 |
$32,221
565,297
kWh
|
$6,138
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $26,036 | $75,363 |
$21,957
385,210
kWh
|
$4,079
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs