Assessment Year | 2019 |
---|---|
Principal Product | Dietary Supplements |
NAICS | 325411: Medicinal and Botanical Manufacturing |
SIC | 2833: Medicinal Chemicals and Botanical Products |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
250,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $395,965 | 9,360,000 |
kWh
|
$0.042 |
Electricity Demand | $259,651 | 19,334 |
kW-mo/yr
|
$13.43 |
Electricity Fees | $134,211 | - |
|
- |
TOTAL YEARLY COSTS | $789,827 | |||
RECOMMENDED SAVINGS* | $43,167 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,924 | $37,163 |
$12,942
305,966
kWh
|
$9,982
-
kW-mo/yr
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,730 | $10,305 |
$6,058
143,225
kWh
|
$4,672
-
kW-mo/yr
|
|
03 | 2.7145: Install skylights | $4,029 | $14,835 |
$4,029
95,251
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,578 | $900 |
$2,020
47,750
kWh
|
$1,558
-
kW-mo/yr
|
|
05 | 2.6231: Utilize controls to operate equipment only when needed | $1,906 | $420 |
$1,076
25,428
kWh
|
$830
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $43,167 | $63,623 |
$26,125
617,620
kWh
|
$17,042
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs