| Assessment Year | 2017 |
|---|---|
| Principal Product | Acrylic Hot Tubs |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3088: Plastics Plumbing Fixtures |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
100,000
ft2
|
| Annual Production | 12,000
units
|
| Production Hrs. Annual | 3,188
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $143,532 | 2,084,590 |
kWh
|
$0.069 | |
| Electricity Demand | $35,030 | 6,971 |
kW-mo/yr
|
$5.03 | |
| Electricity Fees | $488 | - |
|
- | |
| Natural Gas | $12,743 | 1,272 |
MMBtu
|
$10.01 | |
| Waste Disposal Costs | |||||
| Water Usage | $7,828 | 2,010 |
Tgal
|
$3.89 | |
| TOTAL YEARLY COSTS | $199,621 | ||||
| RECOMMENDED SAVINGS* | $30,397 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4224: Upgrade controls on compressors | $25,870 | $7,794 |
$21,042
304,960
kWh
|
$4,828
-
kW-mo/yr
|
|
| 02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,847 | $5,691 |
$2,847
41,263
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,680 | $720 |
$1,680
24,353
kWh
|
- | |
| TOTAL RECOMMENDED | $30,397 | $14,205 |
$25,569
370,576
kWh
|
$4,828
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs