Assessment Year | 2023 |
---|---|
Principal Product | Coffee |
NAICS | 311920: Coffee and Tea Manufacturing |
SIC | 2095: Roasted Coffee |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
322,841
ft2
|
Annual Production | 35,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $542,666 | 6,900,195 |
kWh
|
$0.079 |
Electricity Demand | $144,752 | 18,989 |
kW-mo/yr
|
$7.62 |
Electricity Fees | $35,756 | - |
|
- |
Natural Gas | $764,573 | 63,392 |
MMBtu
|
$12.06 |
TOTAL YEARLY COSTS | $1,487,747 | |||
RECOMMENDED SAVINGS* | $80,677 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $712 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $31,464 | $8,591 |
$29,909
380,523
kWh
|
$1,555 | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $27,216 | $2,500 |
$25,871
329,144
kWh
|
$1,345 | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $14,476 | $81,775 |
$13,760
175,069
kWh
|
$716 | |
04 | 2.3212: Optimize plant power factor | $3,523 | $4,208 | - | $3,523 | |
05 | 2.7135: Install occupancy sensors | $3,286 | $3,921 |
$3,124
39,749
kWh
|
$162 | |
06 | 2.8114: Change rate schedules or other changes in utility service | $712 | $800 | - | $712 | |
TOTAL RECOMMENDED | $80,677 | $101,795 |
$72,664
924,485
kWh
|
$8,013 | ||
TOTAL IMPLEMENTED | $712 | $800 | - | $712 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs