Assessment Year 2005
Principal Product Automotive/aircraft parts
NAICS 336412: Aircraft Engine and Engine Parts Manufacturing
SIC 3724: Aircraft Engines and Engine Parts
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 135,000
ft2
Annual Production 150,000,000
pieces
Production Hrs. Annual 8,568
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $436,954 7,211,154
kWh
Electricity Demand $97,015 42,365
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $119,018 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $119,018

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $37,489 $5,000 $35,599
497,893
kWh
$1,890
-
kW-mo/yr
02 2.4231: Reduce the pressure of compressed air to the minimum required $37,178 $15,000 $35,582
497,655
kWh
$1,596
-
kW-mo/yr
03 2.4231: Reduce the pressure of compressed air to the minimum required $23,601 $2,000 $22,411
313,433
kWh
$1,190
-
kW-mo/yr
04 2.4226: Use / purchase optimum sized compressor $15,470 $14,400 $14,690
205,451
kWh
$780
-
kW-mo/yr
05 2.7142: Utilize higher efficiency lamps and/or ballasts $4,173 $10,610 $3,994
55,863
kWh
$179
-
kW-mo/yr
06 2.7124: Make a practice of turning off lights when not needed $762 $25 $718
10,046
kWh
$44
-
kW-mo/yr
07 2.9112: Use solar heat to heat water $345 $2,800 $343
4,801
kWh
$2
-
kW-mo/yr
TOTAL RECOMMENDED $119,018 $49,835 $113,337
1,585,142
kWh
$5,681
-
kW-mo/yr
TOTAL IMPLEMENTED $119,018 $49,835 $113,337
1,585,142
kWh
$5,681
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs