Assessment Year 2005
Principal Product Evaporative coolets
NAICS 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 60,000
ft2
Annual Production 60,000
pieces
Production Hrs. Annual 2,080
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $150,503 1,877,127
kWh
Natural Gas $140,318 16,555
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $24,629 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,679

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1213: Direct warmest air to combustion intake $7,503 $6,000 - $7,503
-
MMBtu
02 2.4323: Use optimum size and capacity equipment $7,150 $6,600 $7,150
87,194
kWh
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $5,623 $100 $5,623
68,574
kWh
-
04 2.7134: Use photocell controls - $5,538 - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,056 $1,000 $2,056
25,106
kWh
-
06 2.4226: Use / purchase optimum sized compressor $1,603 $7,200 $1,603
19,552
kWh
-
07 2.9112: Use solar heat to heat water $591 $3,200 $591
7,202
kWh
-
08 2.2136: Install / repair insulation on steam lines $103 $689 - $103
-
MMBtu
TOTAL RECOMMENDED $24,629 $30,327 $17,023
207,628
kWh
$7,606
-
MMBtu
TOTAL IMPLEMENTED $7,679 $6,638 $7,679
93,680
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs