Assessment Year | 2005 |
---|---|
Principal Product | Paper bags |
NAICS | 322212: Folding Paperboard Box Manufacturing |
SIC | 2621: Paper Mills |
Sales Range | $50 M to 100M |
# of Employees | 140 |
Plant Area |
121,000
ft2
|
Annual Production | 33,600
ton
|
Production Hrs. Annual | 6,072
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $511,350 | 6,288,996 |
kWh
|
$0.081 |
Natural Gas | $10,035 | 1,115 |
MMBtu
|
$9.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $46,483 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $19,404 | $11,000 |
$19,404
271,389
kWh
|
- | |
02 | 2.4224: Upgrade controls on compressors | $13,305 | $10,000 |
$13,305
185,086
kWh
|
- | |
03 | 2.4226: Use / purchase optimum sized compressor | $7,055 | $8,000 |
$7,055
98,669
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,097 | $10,861 |
$2,097
40,370
kWh
|
- | |
05 | 2.7134: Use photocell controls | $1,730 | $4,650 |
$1,730
24,192
kWh
|
- | |
06 | 2.1213: Direct warmest air to combustion intake | $1,337 | $1,000 | - |
$1,337
-
MMBtu
|
|
07 | 2.9112: Use solar heat to heat water | $1,555 | $12,000 |
$1,555
21,605
kWh
|
- | |
TOTAL RECOMMENDED | $46,483 | $57,511 |
$45,146
641,311
kWh
|
$1,337
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs