| Assessment Year | 2005 |
|---|---|
| Principal Product | Paper bags |
| NAICS | 322212: Folding Paperboard Box Manufacturing |
| SIC | 2621: Paper Mills |
| Sales Range | $50 M to 100M |
| # of Employees | 140 |
| Plant Area |
121,000
ft2
|
| Annual Production | 33,600
ton
|
| Production Hrs. Annual | 6,072
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $511,350 | 6,288,996 |
kWh
|
$0.081 |
| Natural Gas | $10,035 | 1,115 |
MMBtu
|
$9.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,483 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $19,404 | $11,000 |
$19,404
271,389
kWh
|
- | |
| 02 | 2.4224: Upgrade controls on compressors | $13,305 | $10,000 |
$13,305
185,086
kWh
|
- | |
| 03 | 2.4226: Use / purchase optimum sized compressor | $7,055 | $8,000 |
$7,055
98,669
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,097 | $10,861 |
$2,097
40,370
kWh
|
- | |
| 05 | 2.7134: Use photocell controls | $1,730 | $4,650 |
$1,730
24,192
kWh
|
- | |
| 06 | 2.1213: Direct warmest air to combustion intake | $1,337 | $1,000 | - |
$1,337
-
MMBtu
|
|
| 07 | 2.9112: Use solar heat to heat water | $1,555 | $12,000 |
$1,555
21,605
kWh
|
- | |
| TOTAL RECOMMENDED | $46,483 | $57,511 |
$45,146
641,311
kWh
|
$1,337
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs