| Assessment Year | 2000 |
|---|---|
| Principal Product | Vinyl Windows & Doors |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 33 |
| Plant Area |
40,000
ft2
|
| Annual Production | 18,000
pieces
|
| Production Hrs. Annual | 2,201
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $7,266 | 110,199 |
kWh
|
$0.066 |
| Electricity Demand | $1,254 | 508 |
kW-mo/yr
|
$2.47 |
| Electricity Fees | $939 | - |
|
- |
| Natural Gas | $512 | 37 |
MMBtu
|
$13.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $948 | $920 |
$948
16,706
kWh
|
- | - | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,057 | $120 |
$675
12,016
kWh
|
$382
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7261: Install timers and/or thermostats | $157 | $150 |
$157
2,931
kWh
|
- | - | - | - | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $470 | $1,000 |
$387
6,741
kWh
|
$83
-
kW-mo/yr
|
- | - | - | |
| 05 | 3.6192: Use a less expensive method of waste removal | $3,780 | $60 | - | - |
$3,780
-
lb
|
- | - | |
| 06 | 3.5313: Increase amount of waste recovered for resale | $3,270 | $120 | - | - |
$3,270
-
lb
|
- | - | |
| 07 | 4.812: Apply for investment incentives | $137 | $60 | - | - | - | $94 | $43 | |
| 08 | 4.511: Expand operations into unused space | $10,475 | $3,200 | - | - | - | $10,475 | - | |
| TOTAL RECOMMENDED | $20,294 | $5,630 |
$2,167
38,394
kWh
|
$465
-
kW-mo/yr
|
$7,050
-
lb
|
$10,569 | $43 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs