Assessment Year | 2000 |
---|---|
Principal Product | Embroidery |
NAICS |
n/a
|
SIC | 2329: Men's and Boys' Clothing, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
91,000
ft2
|
Annual Production | 1,600,000
pieces
|
Production Hrs. Annual | 6,467
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $123,753 | 1,353,458 |
kWh
|
$0.091 |
Electricity Demand | $6,906 | 5,057 |
kW-mo/yr
|
$1.37 |
Electricity Fees | $10,593 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $662,082 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,649 | $30,357 | n/a |
$11,813
155,920
kWh
|
$1,836
-
kW-mo/yr
|
- | - | - | - |
02 | 2.7135: Install occupancy sensors | $2,547 | $2,475 | n/a |
$2,292
30,188
kWh
|
$255
-
kW-mo/yr
|
- | - | - | - |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,204 | $1,012 | n/a |
$769
10,258
kWh
|
$59
-
kW-mo/yr
|
- | $210 | - | $166 |
04 | 2.7145: Install skylights | $2,171 | $1,680 | n/a |
$2,171
28,722
kWh
|
- | - | - | - | - |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $29,540 | $31,800 | n/a |
$26,932
355,217
kWh
|
$2,608
-
kW-mo/yr
|
- | - | - | - |
06 | 3.6192: Use a less expensive method of waste removal | $2,700 | $60 | n/a | - | - | - | - | $2,700 | - |
07 | 3.6192: Use a less expensive method of waste removal | $1,608 | $60 | n/a | - | - | - | - | $1,608 | - |
08 | 4.512: Condense operation into one building | $604,757 | $2,250,000 | n/a | - |
$(-1,867.0)
-
kW-mo/yr
|
$21,599 | - | $585,025 | - |
09 | 4.231: Purchase equipment instead of leasing | $3,906 | $12,060 | n/a | - | - | - | - | $3,906 | - |
TOTAL RECOMMENDED | $662,082 | $2,329,504 |
$43,977
580,305
kWh
|
$2,891
-
kW-mo/yr
|
$21,599 | $210 | $593,239 | $166 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs