Assessment Year | 1999 |
---|---|
Principal Product | Paper Products |
NAICS |
n/a
|
SIC | 2679: Converted Paper and Paperboard Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
90,000
ft2
|
Annual Production | 9,000
thousand feet
|
Production Hrs. Annual | 2,375
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,658 | 492,966 |
kWh
|
$0.064 |
Electricity Demand | $4,641 | 1,777 |
kW-mo/yr
|
$2.61 |
Electricity Fees | $3,097 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $140,061 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,077 | $3,520 |
$757
13,482
kWh
|
$320
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,413 | $5,527 |
$2,413
42,790
kWh
|
- | - | - | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $318 | $60 |
$88
1,465
kWh
|
$230
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7261: Install timers and/or thermostats | $540 | $750 |
$540
9,672
kWh
|
- | - | - | - | - | |
05 | 3.5217: Reuse / recycle/ sell paper products | $1,073 | $120 | - | - |
$(-802.0)
-
lb
|
$1,875 | - | - | |
06 | 4.821: Pay bills on time to avoid late fees | $390 | $60 | - | - | - | - | $390 | - | |
07 | 4.112: Replace old machine with new automatic multi-station tool | $63,000 | $67,220 | - | - | - | - | - | $63,000 | |
08 | 4.513: Re-arrange equipment layout to reduce labor costs | $71,250 | $300 | - | - | - | $71,250 | - | - | |
TOTAL RECOMMENDED | $140,061 | $77,557 |
$3,798
67,409
kWh
|
$550
-
kW-mo/yr
|
$(-802.0)
-
lb
|
$73,125 | $390 | $63,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs