Assessment Year | 1998 |
---|---|
Principal Product | Machinery and Subassemblies for Semiconductor Equipment |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 115 |
Plant Area |
46,000
ft2
|
Annual Production | 23,000
pieces
|
Production Hrs. Annual | 4,896
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,151 | 2,038,980 |
kWh
|
$0.056 |
Electricity Demand | $10,582 | 3,784 |
kW-mo/yr
|
$2.80 |
Electricity Fees | $9,776 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,607 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $901 | $1,875 |
$901
23,154
kWh
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,256 | $16,930 |
$4,623
118,406
kWh
|
$2,633
-
kW-mo/yr
|
- | - | - | |
03 | 3.6192: Use a less expensive method of waste removal | $1,014 | $60 | - | - |
$1,014
-
lb
|
- | - | |
04 | 4.812: Apply for investment incentives | $1,436 | $60 | - | - | - | $1,280 | $156 | |
TOTAL RECOMMENDED | $10,607 | $18,925 |
$5,524
141,560
kWh
|
$2,633
-
kW-mo/yr
|
$1,014
-
lb
|
$1,280 | $156 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs