Assessment Year 1996
Principal Product Potato and Corn Chip Snacks
NAICS
n/a
SIC 2096: Potato Chips, Corn Chips, and Similar Snacks
Sales Range $100
M
to 500
M
# of Employees 300
Plant Area 180,000
ft2
Annual Production 25,000
ton
Production Hrs. Annual 7,488
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $529,187 8,423,798
kWh
Electricity Demand $27,454 14,070
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,289 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,882

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,388 $10,000 $6,879
145,955
kWh
$509
-
kW-mo/yr
-
02 2.7232: Replace existing hvac unit with high efficiency model $8,466 $4,200 $7,229
153,283
kWh
$1,237
-
kW-mo/yr
-
03 2.7261: Install timers and/or thermostats $932 $2,080 $932
19,930
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $119 $115 $113
2,345
kWh
$6
-
kW-mo/yr
-
05 2.4133: Use most efficient type of electric motors $8,795 $6,778 $8,228
174,678
kWh
$567
-
kW-mo/yr
-
06 2.2622: Replace existing chiller with high efficiency model $2,455 $3,500 $3,234
80,305
kWh
$407
-
kW-mo/yr
$(-1,186.0)
-
Tgal
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $283 - $266
5,569
kWh
$17
-
kW-mo/yr
-
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,148 $5,730 $1,010
21,395
kWh
$138
-
kW-mo/yr
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $6,607 $26,161 $6,090
129,250
kWh
$517
-
kW-mo/yr
-
10 3.4154: Eliminate leaks in water lines and valves $96 $100 - - $96
-
Tgal
TOTAL RECOMMENDED $36,289 $58,664 $33,981
732,710
kWh
$3,398
-
kW-mo/yr
$(-1,090.0)
-
Tgal
TOTAL IMPLEMENTED $16,882 $16,380 $15,040
319,168
kWh
$1,746
-
kW-mo/yr
$96
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs