Assessment Year 1996
Principal Product Pasta Food Products
NAICS
n/a
SIC 2098: Macaroni, Spaghetti, Vermicelli, and Noodles
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 300,000
ft2
Annual Production 43,500
ton
Production Hrs. Annual 8,568
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $762,323 15,939,332
kWh
Electricity Demand $176,820 77,852
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $108,081 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $85,241

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,604 - $1,504
32,239
kWh
$100
-
kW-mo/yr
-
02 2.4133: Use most efficient type of electric motors $18,978 $14,977 $17,438
379,836
kWh
$1,540
-
kW-mo/yr
-
03 2.7135: Install occupancy sensors $2,295 $1,350 $2,295
49,238
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $7,307 $9,177 $6,930
148,593
kWh
$377
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,240 $5,343 $2,021
43,376
kWh
$219
-
kW-mo/yr
-
06 2.2622: Replace existing chiller with high efficiency model $63,244 $50,000 $58,508
1,253,224
kWh
$4,736
-
kW-mo/yr
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $9,003 - $8,414
180,246
kWh
$589
-
kW-mo/yr
-
08 2.7261: Install timers and/or thermostats $391 $320 $391
8,499
kWh
- -
09 3.4156: Use flow control valves on equipment to optimize water use $1,648 $30 - - $1,648
-
Tgal
10 3.4156: Use flow control valves on equipment to optimize water use $330 $30 - - $330
-
Tgal
11 3.4154: Eliminate leaks in water lines and valves $1,041 $1,780 - - $1,041
-
Tgal
TOTAL RECOMMENDED $108,081 $83,007 $97,501
2,095,251
kWh
$7,561
-
kW-mo/yr
$3,019
-
Tgal
TOTAL IMPLEMENTED $85,241 $66,817 $75,946
1,633,060
kWh
$6,276
-
kW-mo/yr
$3,019
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs