| Assessment Year | 1995 |
|---|---|
| Principal Product | Kitchen and Bath Cabinets |
| NAICS |
n/a
|
| SIC | 2434: Wood Kitchen Cabinets |
| Sales Range | $50 M to 100M |
| # of Employees | 280 |
| Plant Area |
181,500
ft2
|
| Annual Production | 488,379
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $127,251 | 1,361,079 |
kWh
|
$0.093 |
| Natural Gas | $7,416 | 1,584 |
MMBtu
|
$4.68 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,233 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,199 | $2,108 |
$1,199
9,672
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $388 | - |
$388
3,517
kWh
|
|
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,380 | $2,600 |
$2,380
21,395
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $554 | $240 |
$554
5,275
kWh
|
|
| 05 | 2.4221: Install compressor air intakes in coolest locations | $238 | $200 |
$238
2,345
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,282 | $9,274 |
$3,282
37,222
kWh
|
|
| 07 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $358 | $100 |
$358
6,448
kWh
|
|
| 08 | 2.7111: Reduce illumination to minimum necessary levels | $2,009 | $700 |
$2,009
23,447
kWh
|
|
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,111 | $3,204 |
$1,111
12,896
kWh
|
|
| 10 | 2.7135: Install occupancy sensors | $741 | $1,350 |
$741
13,482
kWh
|
|
| TOTAL RECOMMENDED | $12,260 | $19,776 |
$12,260
135,699
kWh
|
||
| TOTAL IMPLEMENTED | $6,233 | $10,214 |
$6,233
69,461
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs