Assessment Year | 1994 |
---|---|
Principal Product | truck bodies |
NAICS |
n/a
|
SIC | 3713: Truck and Bus Bodies |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
81,600
ft2
|
Annual Production | 4,000
pieces
|
Production Hrs. Annual | 3,575
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $120,045 | 1,113,423 |
kWh
|
$0.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,344 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,141 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $3,476 | $3,000 |
$3,476
32,239
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,783 | $2,800 |
$5,783
53,634
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $2,051 | $2,241 |
$2,051
19,050
kWh
|
|
04 | 2.6218: Turn off equipment when not in use | $1,552 | $360 |
$1,552
14,361
kWh
|
|
05 | 2.7132: Install timers on light switches in little used areas | $878 | $1,575 |
$878
8,206
kWh
|
|
06 | 2.7134: Use photocell controls | $1,809 | $390 |
$1,809
16,706
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,651 | $7,224 |
$2,651
24,619
kWh
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,144 | $1,902 |
$1,144
10,551
kWh
|
|
TOTAL RECOMMENDED | $19,344 | $19,492 |
$19,344
179,366
kWh
|
||
TOTAL IMPLEMENTED | $15,141 | $11,908 |
$15,141
140,386
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs