Assessment Year | 1993 |
---|---|
Principal Product | GROUND BEEF |
NAICS |
n/a
|
SIC | 2011: Meat Packing Plants |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 2,800
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $126,938 | 1,456,331 |
kWh
|
$0.087 |
Natural Gas | $16,367 | 3,731 |
MMBtu
|
$4.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,723 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,783 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,735 | $1,153 |
$1,735
19,930
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,945 | - |
$4,945
56,858
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $610 | $250 |
$610
7,034
kWh
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $720 | $1,584 |
$720
8,206
kWh
|
- | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $201 | $500 | - |
$201
-
MMBtu
|
- | |
06 | 2.2136: Install / repair insulation on steam lines | $964 | $463 | - |
$964
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $196 | - |
$227
2,638
kWh
|
- | $(-31.0) | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $138 | $272 |
$138
1,465
kWh
|
- | - | |
09 | 2.7135: Install occupancy sensors | $195 | $236 |
$195
2,345
kWh
|
- | - | |
10 | 2.6232: Install set-back timers | $1,019 | $1,005 |
$1,019
11,723
kWh
|
- | - | |
TOTAL RECOMMENDED | $10,723 | $5,463 |
$9,589
110,199
kWh
|
$1,165
-
MMBtu
|
$(-31.0) | ||
TOTAL IMPLEMENTED | $8,783 | $2,374 |
$7,850
90,270
kWh
|
$964
-
MMBtu
|
$(-31.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs