Assessment Year | 1992 |
---|---|
Principal Product | PLASTIC INJECTION MOLDS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
n/a
|
Annual Production | 840,000,000
pieces
|
Production Hrs. Annual | 8,592
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $141,884 | 2,363,130 |
kWh
|
$0.060 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,584 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,170 | $300 |
$8,170
135,991
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,051 | $1,000 |
$1,051
17,585
kWh
|
- | |
03 | 2.4312: Improve lubrication practices | $845 | $1,638 |
$845
14,068
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $1,379 | $9,635 |
$1,379
22,860
kWh
|
- | |
05 | 2.6231: Utilize controls to operate equipment only when needed | $5,602 | $1,008 |
$5,602
93,200
kWh
|
- | |
06 | 2.2511: Insulate bare equipment | $1,860 | $9,880 |
$1,860
31,067
kWh
|
- | |
07 | 2.7226: Use computer programs to optimize hvac performance | $4,740 | $9,000 |
$4,740
78,839
kWh
|
- | |
08 | 2.7422: Plant trees or shrubs near windows to shield from sunlight | $840 | $3,100 |
$840
14,068
kWh
|
- | |
09 | 2.7221: Lower temperature during the winter season and vice-versa | $8,777 | - |
$8,777
146,249
kWh
|
- | |
10 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,506 | $10,500 |
$2,506
41,618
kWh
|
- | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,443 | $469 |
$4,796
80,012
kWh
|
$(-353.0) | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,371 | $13,077 |
$1,371
22,860
kWh
|
- | |
TOTAL RECOMMENDED | $41,584 | $59,607 |
$41,937
698,417
kWh
|
$(-353.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs