Assessment Year 1992
Principal Product CAPACITORS
NAICS
n/a
SIC 3675: Electronic Capacitors
Sales Range $5
M
to 10
M
# of Employees 40
Plant Area
n/a
Annual Production 4,500,000
pieces
Production Hrs. Annual 2,340
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $107,507 1,588,511
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $16,491 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $229 $95 $257
3,810
kWh
$(-28.0)
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,819 $16,774 $4,819
71,219
kWh
-
03 2.4133: Use most efficient type of electric motors $80 $1,598 $80
1,172
kWh
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $114 - $114
1,758
kWh
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $428 $300 $428
6,448
kWh
-
06 2.7221: Lower temperature during the winter season and vice-versa $2,572 - $2,572
38,101
kWh
-
07 2.7261: Install timers and/or thermostats $3,843 $1,600 $3,843
56,858
kWh
-
08 2.7422: Plant trees or shrubs near windows to shield from sunlight $714 $1,800 $714
10,551
kWh
-
09 2.7226: Use computer programs to optimize hvac performance $3,692 $5,400 $3,692
54,513
kWh
-
TOTAL RECOMMENDED $16,491 $27,567 $16,519
244,430
kWh
$(-28.0)
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs