Assessment Year 1992
Principal Product PLASTIC INJECTION MOLDS
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 135
Plant Area
n/a
Annual Production 312,000
pieces
Production Hrs. Annual 8,640
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $383,379 5,818,582
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $57,903 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $39,110

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.4322: Use or replace with energy efficient substitutes $27,304 $96,000 $27,304
414,420
kWh
-
02 2.4133: Use most efficient type of electric motors $2,779 $9,821 $2,779
42,204
kWh
-
03 2.7422: Plant trees or shrubs near windows to shield from sunlight $733 $1,500 $733
11,137
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $42 $332 $120
1,758
kWh
$(-78.0)
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,444 $6,291 $1,444
21,981
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,983 $1,280 $1,983
30,188
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $645 $1,512 $645
9,672
kWh
-
08 2.6232: Install set-back timers $3,474 $200 $3,474
52,755
kWh
-
09 2.2437: Recover waste heat from equipment $4,913 $4,491 $4,913
74,443
kWh
-
10 2.6212: Turn off equipment during breaks, reduce operating time $14,267 $1,512 $14,267
216,589
kWh
-
11 2.4322: Use or replace with energy efficient substitutes $319 - $319
3,224
kWh
-
TOTAL RECOMMENDED $57,903 $122,939 $57,981
878,371
kWh
$(-78.0)
TOTAL IMPLEMENTED $39,110 $119,727 $39,188
594,666
kWh
$(-78.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs