Assessment Year 1992
Principal Product 3-RING BINDERS
NAICS
n/a
SIC 2782: Blankbooks, Looseleaf Binders and Devices
Sales Range $5
M
to 10
M
# of Employees 83
Plant Area
n/a
Annual Production 12,600,000
pieces
Production Hrs. Annual 4,536
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $98,354 1,120,164
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,990 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,719

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.7226: Use computer programs to optimize hvac performance $8,626 $3,200 $8,626
98,183
kWh
-
02 2.7123: Keep lamps and reflectors clean $8,054 $8,825 $8,054
91,735
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,876 $4,421 $1,936
22,274
kWh
$(-60.0)
04 2.7123: Keep lamps and reflectors clean $1,217 $3,420 $1,217
13,775
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $345 $3,363 $437
4,982
kWh
$(-92.0)
06 2.4133: Use most efficient type of electric motors $270 $774 $270
3,224
kWh
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $377 - $377
4,396
kWh
-
08 2.4231: Reduce the pressure of compressed air to the minimum required $998 - $998
11,430
kWh
-
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $663 $100 $663
7,620
kWh
-
10 2.4221: Install compressor air intakes in coolest locations $564 $500 $564
6,448
kWh
-
TOTAL RECOMMENDED $22,990 $24,603 $23,142
264,067
kWh
$(-152.0)
TOTAL IMPLEMENTED $13,719 $12,358 $13,871
158,557
kWh
$(-152.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs