ITAC Assessment: AS0010
ITAC logo
ITAC Assessment: AS0010
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1990
Principal Product ALUMINUM WINDOWS & DOORS
NAICS
n/a
SIC 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing
Sales Range $10
M
to 50
M
# of Employees 527
Plant Area
n/a
Annual Production 1,200,000
pieces
Production Hrs. Annual 7,116
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $447,336 6,264,068
kWh
Natural Gas $94,064 25,796
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $53,053 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,348

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,459 - $1,459
20,516
kWh
-
02 2.4133: Use most efficient type of electric motors $591 $758 $591
8,499
kWh
-
03 2.2511: Insulate bare equipment $3,149 $261 $3,149
44,549
kWh
-
04 2.2511: Insulate bare equipment $7,665 $2,474 - $7,665
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,125 $2,587 $1,125
15,826
kWh
-
06 2.7123: Keep lamps and reflectors clean $17,065 $13,365 $17,065
240,914
kWh
-
07 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads $16,359 $6,000 $16,359
230,950
kWh
-
08 2.6231: Utilize controls to operate equipment only when needed $5,640 $1,000 $5,640
79,719
kWh
-
TOTAL RECOMMENDED $53,053 $26,445 $45,388
640,973
kWh
$7,665
-
MMBtu
TOTAL IMPLEMENTED $30,348 $12,080 $22,683
320,340
kWh
$7,665
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs