Assessment Year | 2012 |
---|---|
Principal Product | Dairy Processing |
NAICS | 311511: Fluid Milk Manufacturing |
SIC | 2026: Fluid Milk |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
30,169
ft2
|
Annual Production | 9,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,900 | 1,844,400 |
kWh
|
$0.055 |
Electricity Demand | $26,289 | 3,980 |
kW-mo/yr
|
$6.61 |
Natural Gas | $8,043 | 1,210 |
MMBtu
|
$6.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,045 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,051 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2626: Avoid frost formation on evaporators | $3,140 | $2,412 |
$2,190
37,927
kWh
|
$950
-
kW-mo/yr
|
- | - | - | |
02 | 2.2531: Re-size charging openings or add movable cover or door | $2,994 | $10,000 |
$2,994
51,846
kWh
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,663 | $19,592 |
$4,180
72,375
kWh
|
$306
-
kW-mo/yr
|
- | $561 | $1,616 | |
04 | 2.1231: Establish burner maintenance schedule for boilers | $6,078 | $500 | - | - |
$6,578
-
MMBtu
|
$(-500.0) | - | |
05 | 2.2136: Install / repair insulation on steam lines | $1,391 | $3,854 |
$1,391
57,604
kWh
|
- | - | - | - | |
06 | 2.2531: Re-size charging openings or add movable cover or door | $2,779 | $6,600 |
$2,779
48,116
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $23,045 | $42,958 |
$13,534
267,868
kWh
|
$1,256
-
kW-mo/yr
|
$6,578
-
MMBtu
|
$61 | $1,616 | ||
TOTAL IMPLEMENTED | $20,051 | $32,958 |
$10,540
216,022
kWh
|
$1,256
-
kW-mo/yr
|
$6,578
-
MMBtu
|
$61 | $1,616 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs