Assessment Year 2005
Principal Product Grain milling and sorting
NAICS 311212: Rice Milling
SIC 2044: Rice Milling
Sales Range $5
M
to 10
M
# of Employees 41
Plant Area 40,000
ft2
Annual Production 22,500,000
lb
Production Hrs. Annual 2,080
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $12,688 236,693
kWh
Electricity Demand $10,328 1,368
kW-mo/yr
Electricity Fees $1,557 -
Natural Gas $9,888 1,169
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $76,149 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,174

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Fuel Oil #1 Savings Water Disposal Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4239: Eliminate or reduce compressed air usage $5,478 $2,000 $5,115
95,428
kWh
- $363 - - - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,091 $580 $1,261
19,086
kWh
$830
-
kW-mo/yr
- - - - - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,261 $500 - - $38 $10,223
-
MMBtu
- - - -
04 2.7135: Install occupancy sensors $241 - $225
4,202
kWh
- $16 - - - - -
05 2.4231: Reduce the pressure of compressed air to the minimum required $211 - $197
3,669
kWh
- $14 - - - - -
06 2.7231: Use radiant heater for spot heating $123 - - - - - $123
-
MMBtu
- - -
07 3.4151: Minimize water usage $1,344 - - - - - - $1,344
-
Tgal
- -
08 4.611: Begin a practice of predictive / preventative maintenance $56,400 $490 - - - - - - $53,900 $2,500
TOTAL RECOMMENDED $76,149 $3,570 $6,798
122,385
kWh
$830
-
kW-mo/yr
$431 $10,223
-
MMBtu
$123
-
MMBtu
$1,344
-
Tgal
$53,900 $2,500
TOTAL IMPLEMENTED $19,174 $3,080 $6,376
114,514
kWh
$830
-
kW-mo/yr
$401 $10,223
-
MMBtu
- $1,344
-
Tgal
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Fuel Oil #1 Savings Water Disposal Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs