| Assessment Year | 1990 |
|---|---|
| Principal Product | LAMINATED CIRCUIT BOARDS |
| NAICS |
n/a
|
| SIC | 3672: Printed Circuit Boards |
| Sales Range | $5 M to 10M |
| # of Employees | 55 |
| Plant Area |
n/a
|
| Annual Production | 3,000
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $126,440 | 2,014,947 |
kWh
|
$0.063 |
| Natural Gas | $19,681 | 3,548 |
MMBtu
|
$5.55 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,800 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $267 | $61 |
$267
4,103
kWh
|
- | |
| 02 | 2.7123: Keep lamps and reflectors clean | $5,940 | $15,120 |
$5,940
94,666
kWh
|
- | |
| 03 | 2.6232: Install set-back timers | $2,168 | $1,275 |
$2,168
34,584
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $393 | $702 |
$393
6,155
kWh
|
- | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,032 | $1,000 | - |
$1,032
-
MMBtu
|
|
| TOTAL RECOMMENDED | $9,800 | $18,158 |
$8,768
139,508
kWh
|
$1,032
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs