Assessment Year | 1998 |
---|---|
Principal Product | Office Furniture |
NAICS |
n/a
|
SIC | 2521: Wood Office Furniture |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
125,530
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 3,128
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,215 | 2,546,014 |
kWh
|
$0.032 |
Electricity Demand | $48,904 | 7,245 |
kW-mo/yr
|
$6.75 |
Natural Gas | $91,056 | 22,203 |
MMBtu
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,014 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,715 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $613 | $210 |
$338
10,551
kWh
|
$275
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.2511: Insulate bare equipment | $492 | $132 | - | - |
$492
-
MMBtu
|
- | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $288 | $668 |
$151
4,689
kWh
|
$137
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $755 | - |
$396
12,309
kWh
|
$359
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $3,840 | $240 |
$1,930
60,375
kWh
|
$1,910
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.8142: Distill contaminated solvents for reuse | $9,519 | $6,000 |
$(-148.0)
(-2,638)
kWh
|
- | - |
$4,332
-
gal
|
- | $5,335 | |
07 | 4.111: Add equipment/ operators to reduce production bottleneck | $7,507 | $125 | - | - | - | - | $7,507 | - | |
TOTAL RECOMMENDED | $23,014 | $7,375 |
$2,667
85,286
kWh
|
$2,681
-
kW-mo/yr
|
$492
-
MMBtu
|
$4,332
-
gal
|
$7,507 | $5,335 | ||
TOTAL IMPLEMENTED | $12,715 | $575 |
$2,664
83,235
kWh
|
$2,544
-
kW-mo/yr
|
- | - | $7,507 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs