| Assessment Year | 1998 |
|---|---|
| Principal Product | Women's Shoes |
| NAICS |
n/a
|
| SIC | 3144: Women's Footwear, Except Athletic |
| Sales Range | $5 M to 10M |
| # of Employees | 125 |
| Plant Area |
40,000
ft2
|
| Annual Production | 200,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $57,120 | 798,359 |
kWh
|
$0.072 |
| Electricity Demand | $11,469 | 3,359 |
kW-mo/yr
|
$3.41 |
| Natural Gas | $7,340 | 1,253 |
MMBtu
|
$5.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,928 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $200 | $70 | n/a |
$163
2,345
kWh
|
$37
-
kW-mo/yr
|
- | - | - |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $142 | $150 | n/a |
$110
1,465
kWh
|
$32
-
kW-mo/yr
|
- | - | - |
| 03 | 2.7245: Use direct air supply to exhaust hoods | $2,608 | $4,328 | n/a |
$1,093
16,413
kWh
|
- |
$1,515
-
MMBtu
|
- | - |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $145 | - | n/a |
$113
1,465
kWh
|
$32
-
kW-mo/yr
|
- | - | - |
| 05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $6,888 | $8,000 | n/a |
$(-112.0)
(-1,465)
kWh
|
$(-34.0)
-
kW-mo/yr
|
- |
$8,220
-
lb
|
$(-1,186.0) |
| 06 | 4.514: Re-arrange equipment layout to reduce handling costs | $16,835 | $6,400 | n/a | - | - | - | - | $16,835 |
| 07 | 3.2176: Increase use of automation | $9,110 | $1,500 | n/a | - | - | - | - | $9,110 |
| TOTAL RECOMMENDED | $35,928 | $20,448 |
$1,367
20,223
kWh
|
$67
-
kW-mo/yr
|
$1,515
-
MMBtu
|
$8,220
-
lb
|
$24,759 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs