| Assessment Year | 1998 |
|---|---|
| Principal Product | Wood Pallets |
| NAICS |
n/a
|
| SIC | 2448: Wood Pallets and Skids |
| Sales Range | $5 M to 10M |
| # of Employees | 65 |
| Plant Area |
52,900
ft2
|
| Annual Production | 76,000,000
lb
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $31,982 | 943,142 |
kWh
|
$0.034 |
| Electricity Demand | $35,880 | 6,395 |
kW-mo/yr
|
$5.61 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $171,467 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $96,957 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $1,315 | $269 |
$760
22,274
kWh
|
$555
-
kW-mo/yr
|
- | - | |
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,297 | - |
$1,297
38,101
kWh
|
- | - | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,920 | - |
$1,078
31,653
kWh
|
$842
-
kW-mo/yr
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $393 | $6,580 |
$222
6,448
kWh
|
$171
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $774 | $90 |
$412
12,309
kWh
|
$362
-
kW-mo/yr
|
- | - | |
| 06 | 2.3212: Optimize plant power factor | $7,882 | $10,035 | - |
$7,882
-
kW-mo/yr
|
- | - | |
| 07 | 3.5313: Increase amount of waste recovered for resale | $23,082 | $44,000 |
$(-9,836.0)
(-35,463)
kWh
|
- |
$32,918
-
lb
|
- | |
| 08 | 4.442: Install magazines for temporary storage | $63,000 | $8,000 | - | - | - | $63,000 | |
| 09 | 4.513: Re-arrange equipment layout to reduce labor costs | $71,804 | $19,800 |
$(-196.0)
(-3,517)
kWh
|
- | - | $72,000 | |
| TOTAL RECOMMENDED | $171,467 | $88,774 |
$(-6,263.0)
71,805
kWh
|
$9,812
-
kW-mo/yr
|
$32,918
-
lb
|
$135,000 | ||
| TOTAL IMPLEMENTED | $96,957 | $63,890 |
$(-8,323.0)
11,430
kWh
|
$362
-
kW-mo/yr
|
$32,918
-
lb
|
$72,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs