Assessment Year | 1997 |
---|---|
Principal Product | Whole Fresh and Frozen Turkeys |
NAICS |
n/a
|
SIC | 2015: Poultry Slaughtering and Processing |
Sales Range | $10 M to 50M |
# of Employees | 485 |
Plant Area |
116,000
ft2
|
Annual Production | 166,083,646
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $397,055 | 19,296,894 |
kWh
|
$0.021 |
Electricity Demand | $186,425 | 43,516 |
kW-mo/yr
|
$4.28 |
Natural Gas | $179,996 | 71,577 |
MMBtu
|
$2.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $285,517 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,945 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Water Disposal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $491 | $180 |
$233
10,844
kWh
|
$258
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $130 | $81 |
$93
4,396
kWh
|
$37
-
kW-mo/yr
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,085 | - |
$559
26,671
kWh
|
$526
-
kW-mo/yr
|
- | - | - | |
04 | 2.2425: Use flue gases to heat process or service water | $4,495 | $16,000 | - | - |
$4,495
-
MMBtu
|
- | - | |
05 | 3.4115: Recover and reuse cooling water | $6,680 | $9,800 | - | - | - |
$6,680
-
Tgal
|
- | |
06 | 3.4156: Use flow control valves on equipment to optimize water use | $5,369 | $200 |
$595
69,461
kWh
|
- | - |
$4,774
-
Tgal
|
- | |
07 | 4.441: Install automatic packing equipment | $143,923 | $406,000 |
$(-1,959.0)
(-49,531)
kWh
|
- | - | - | $145,882 | |
08 | 4.441: Install automatic packing equipment | $123,344 | $597,000 |
$(-1,697.0)
(-42,790)
kWh
|
- | - | - | $125,041 | |
TOTAL RECOMMENDED | $285,517 | $1,029,261 |
$(-2,176.0)
19,051
kWh
|
$821
-
kW-mo/yr
|
$4,495
-
MMBtu
|
$11,454
-
Tgal
|
$270,923 | ||
TOTAL IMPLEMENTED | $6,945 | $380 |
$1,387
106,976
kWh
|
$784
-
kW-mo/yr
|
- |
$4,774
-
Tgal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Water Disposal Savings | Personnel Changes Savings |