| Assessment Year | 1996 |
|---|---|
| Principal Product | Stainless Steel Tubing |
| NAICS |
n/a
|
| SIC | 3317: Steel Pipe and Tubes |
| Sales Range | $50 M to 100M |
| # of Employees | 180 |
| Plant Area |
80,000
ft2
|
| Annual Production | 10,000,000
thousand feet
|
| Production Hrs. Annual | 6,257
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $136,064 | 3,669,988 |
kWh
|
$0.037 |
| Electricity Demand | $33,309 | 7,975 |
kW-mo/yr
|
$4.18 |
| Natural Gas | $132,229 | 42,184 |
MMBtu
|
$3.13 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,137 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,059 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $609 | $355 |
$484
13,189
kWh
|
$125
-
kW-mo/yr
|
- | - | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $369 | $1,000 | - | - |
$369
-
MMBtu
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,047 | $180 |
$892
24,033
kWh
|
$155
-
kW-mo/yr
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,042 | $530 |
$2,538
65,064
kWh
|
$504
-
kW-mo/yr
|
- | - | |
| 05 | 2.4239: Eliminate or reduce compressed air usage | $2,273 | $3,000 |
$1,870
50,410
kWh
|
$403
-
kW-mo/yr
|
- | - | |
| 06 | 2.4133: Use most efficient type of electric motors | $2,389 | $3,380 |
$1,910
51,583
kWh
|
$479
-
kW-mo/yr
|
- | - | |
| 07 | 2.2511: Insulate bare equipment | $307 | $100 | - | - |
$307
-
MMBtu
|
- | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $296 | - |
$218
5,862
kWh
|
$78
-
kW-mo/yr
|
- | - | |
| 09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,805 | $6,000 | - | - | - |
$2,805
-
lb
|
|
| TOTAL RECOMMENDED | $13,137 | $14,545 |
$7,912
210,141
kWh
|
$1,744
-
kW-mo/yr
|
$676
-
MMBtu
|
$2,805
-
lb
|
||
| TOTAL IMPLEMENTED | $8,059 | $5,545 |
$6,042
159,731
kWh
|
$1,341
-
kW-mo/yr
|
$676
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs