| Assessment Year | 1996 |
|---|---|
| Principal Product | Small Mill Equipment |
| NAICS |
n/a
|
| SIC | 3535: Conveyors and Conveying Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
36,000
ft2
|
| Annual Production | 250
pieces
|
| Production Hrs. Annual | 4,693
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $30,088 | 861,958 |
kWh
|
$0.035 |
| Electricity Demand | $34,665 | 4,461 |
kW-mo/yr
|
$7.77 |
| Natural Gas | $9,647 | 2,039 |
MMBtu
|
$4.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,678 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,307 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,611 | $390 |
$655
19,343
kWh
|
$956
-
kW-mo/yr
|
- | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $4,248 | $6,802 |
$2,060
60,668
kWh
|
$2,188
-
kW-mo/yr
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $697 | $1,330 |
$239
7,034
kWh
|
$458
-
kW-mo/yr
|
- | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $147 | $60 |
$72
1,758
kWh
|
$75
-
kW-mo/yr
|
- | - | |
| 05 | 2.7211: Clean and maintain refrigerant condensers and towers | $234 | $30 |
$234
6,741
kWh
|
- | - | - | |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $3,760 | $6,000 | - | - | - |
$3,760
-
lb
|
|
| 07 | 3.8143: Recycle cleaning solvent and reuse | $12,981 | $6,000 | - | - |
$12,981
-
gal
|
- | |
| TOTAL RECOMMENDED | $23,678 | $20,612 |
$3,260
95,544
kWh
|
$3,677
-
kW-mo/yr
|
$12,981
-
gal
|
$3,760
-
lb
|
||
| TOTAL IMPLEMENTED | $18,307 | $14,222 |
$2,605
76,201
kWh
|
$2,721
-
kW-mo/yr
|
$12,981
-
gal
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs