Assessment Year | 1996 |
---|---|
Principal Product | Paper Bags |
NAICS |
n/a
|
SIC | 2674: Uncoated Paper and Multiwall Bags |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
120,000
ft2
|
Annual Production | 38,000,000
pieces
|
Production Hrs. Annual | 5,449
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $103,810 | 2,876,905 |
kWh
|
$0.036 |
Electricity Demand | $59,825 | 7,308 |
kW-mo/yr
|
$8.19 |
Natural Gas | $59,678 | 11,917 |
MMBtu
|
$5.01 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,781 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $64,531 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,305 | $350 |
$8,124
216,002
kWh
|
$4,181
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,857 | $759 |
$1,165
33,411
kWh
|
$692
-
kW-mo/yr
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $3,212 | $1,048 |
$1,972
56,272
kWh
|
$1,240
-
kW-mo/yr
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $817 | $300 |
$817
11,430
kWh
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $4,891 | $8,150 |
$2,978
84,994
kWh
|
$1,913
-
kW-mo/yr
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $652 | $70 |
$397
11,430
kWh
|
$255
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $5,359 | $3,500 |
$3,538
101,114
kWh
|
$1,821
-
kW-mo/yr
|
- | - | |
08 | 2.7224: Reduce space conditioning during non-working hours | $9,526 | $1,900 | - | - |
$9,526
-
MMBtu
|
- | |
09 | 3.1191: Change procedures / equipment / operating conditions | $36,162 | - | - | - | - |
$36,162
-
lb
|
|
TOTAL RECOMMENDED | $74,781 | $16,077 |
$18,991
514,653
kWh
|
$10,102
-
kW-mo/yr
|
$9,526
-
MMBtu
|
$36,162
-
lb
|
||
TOTAL IMPLEMENTED | $64,531 | $4,427 |
$12,475
328,545
kWh
|
$6,368
-
kW-mo/yr
|
$9,526
-
MMBtu
|
$36,162
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs