Assessment Year | 1996 |
---|---|
Principal Product | Aircraft Modification and Maintenance |
NAICS |
n/a
|
SIC | 3721: Aircraft |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
101,097
ft2
|
Annual Production | 120,000
units
|
Production Hrs. Annual | 4,171
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $54,415 | 1,172,626 |
kWh
|
$0.046 |
Electricity Demand | $43,657 | 3,408 |
kW-mo/yr
|
$12.81 |
Natural Gas | $37,594 | 7,807 |
MMBtu
|
$4.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,085 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,796 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $897 | $1,340 |
$455
9,965
kWh
|
$442
-
kW-mo/yr
|
- | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $7,652 | $3,285 |
$3,902
84,994
kWh
|
$3,750
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,945 | $2,535 |
$5,161
112,251
kWh
|
$2,784
-
kW-mo/yr
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $390 | $110 |
$390
8,793
kWh
|
- | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,289 | $6,000 | - | - | - |
$2,289
-
lb
|
|
06 | 3.4151: Minimize water usage | $912 | $10 | - | - |
$912
-
Tgal
|
- | |
TOTAL RECOMMENDED | $20,085 | $13,280 |
$9,908
216,003
kWh
|
$6,976
-
kW-mo/yr
|
$912
-
Tgal
|
$2,289
-
lb
|
||
TOTAL IMPLEMENTED | $17,796 | $7,280 |
$9,908
216,003
kWh
|
$6,976
-
kW-mo/yr
|
$912
-
Tgal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |