Assessment Year | 1996 |
---|---|
Principal Product | Table and Floor Lamps |
NAICS |
n/a
|
SIC | 3645: Residential Electric Lighting Fixtures |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
245,000
ft2
|
Annual Production | 8,000,000
pieces
|
Production Hrs. Annual | 2,738
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,944 | 991,208 |
kWh
|
$0.057 |
Electricity Demand | $37,091 | 4,130 |
kW-mo/yr
|
$8.98 |
Natural Gas | $12,614 | 2,345 |
MMBtu
|
$5.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $95,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,228 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $5,317 | $720 |
$2,852
50,996
kWh
|
$2,465
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,355 | $1,976 |
$2,479
44,256
kWh
|
$1,876
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,725 | $140 |
$983
17,585
kWh
|
$742
-
kW-mo/yr
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $549 | $100 |
$317
5,569
kWh
|
$232
-
kW-mo/yr
|
- | - | |
05 | 2.2437: Recover waste heat from equipment | $6,633 | $100 | - | - |
$6,633
-
MMBtu
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $709 | $1,830 |
$141
2,638
kWh
|
$568
-
kW-mo/yr
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $119 | - |
$57
1,172
kWh
|
$62
-
kW-mo/yr
|
- | - | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $27,454 | $1,488 | - | - | - |
$27,454
-
lb
|
|
09 | 3.1162: Use less wasteful packaging | $48,159 | - | - | - | - |
$48,159
-
lb
|
|
TOTAL RECOMMENDED | $95,020 | $6,354 |
$6,829
122,216
kWh
|
$5,945
-
kW-mo/yr
|
$6,633
-
MMBtu
|
$75,613
-
lb
|
||
TOTAL IMPLEMENTED | $40,228 | $6,254 |
$6,829
122,216
kWh
|
$5,945
-
kW-mo/yr
|
- |
$27,454
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs