| Assessment Year | 1995 |
|---|---|
| Principal Product | Wrinkle-Free Shirts and Pants |
| NAICS |
n/a
|
| SIC | 2329: Men's and Boys' Clothing, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
64,000
ft2
|
| Annual Production | 3,120,000
pieces
|
| Production Hrs. Annual | 6,257
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $199,521 | 2,592,321 |
kWh
|
$0.077 |
| Natural Gas | $82,928 | 21,895 |
MMBtu
|
$3.79 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $111,769 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,958 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $6,271 | $3,600 |
$6,271
84,408
kWh
|
- | - | - | |
| 02 | 2.3212: Optimize plant power factor | $2,641 | $4,320 |
$2,641
-
kWh
|
- | - | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,124 | $300 |
$1,124
15,240
kWh
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,644 | $150 |
$3,644
46,307
kWh
|
- | - | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $6,229 | $5,120 |
$6,229
83,529
kWh
|
- | - | - | |
| 06 | 2.7241: Install outside air damper / economizer on hvac unit | $90,655 | $8,400 |
$90,655
1,353,458
kWh
|
- | - | - | |
| 07 | 2.1213: Direct warmest air to combustion intake | $515 | $600 | - |
$515
-
MMBtu
|
- | - | |
| 08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $515 | $1,000 | - |
$515
-
MMBtu
|
- | - | |
| 09 | 3.4151: Minimize water usage | $175 | $200 | - | - |
$21
-
Tgal
|
$154
-
Tgal
|
|
| TOTAL RECOMMENDED | $111,769 | $23,690 |
$110,564
1,582,942
kWh
|
$1,030
-
MMBtu
|
$21
-
Tgal
|
$154
-
Tgal
|
||
| TOTAL IMPLEMENTED | $17,958 | $10,370 |
$17,268
229,484
kWh
|
$515
-
MMBtu
|
$21
-
Tgal
|
$154
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings | |||